- Product introduction:6 1/2 bit resolution;30 kS/s high-speed sampling frequency, which makes it easy to capture transient signals; front and back multimeter input,measure a key switch;statistic analysis、 histogram and run chart display function;Double display measurement function,display 2 kinds of signal parameters at the same time;3A/10A current range;4.3 inch 64K LCD;0.1uV resolution,easy to use,parameters can be setted easily; 13 kinds of measure functions:DC Voltage, AC Voltage, DC current, AC current, 2 line resistance, 4 line resistance, capacitance, diode, connectivity, frequency, period, Arbitrary sensor, temperature.
- Real 6 1/2 bit reading resolution (2,200,000 count);
- Front and back 2 sets of multimeter input interface,measure can a key switch;
- Up to 30,000 rdgs/s reading;
- Graph display function, trenddrawing function to paperless record teating data,statistic information and histogram;
- Double display measurement function,display 2 kinds of signal parameters at the same time;
- True RMS AC voltage and AC current measure;
- 0.1uV resolution,easy to use, parameters can be setted easily;
- Support dual display, Chinese and English menu;
- Built in help system, convenient access to information;
- 13 kinds of measure functions:DC Voltage, AC Voltage, DC current, AC current, 2 line resistance, 4 line resistance, capacitance, diode, connectivity, frequency, period, Arbitrary sensor, temperature, current range can be 10A;
- 4.3 inch 64K LCD;
- Safety standards is CAT I 1000 V,CAT II 600 V;
- Support standard SCPI Remote control command、upper computer software、Compatible with the latest mainstream multimeter command set;
- Configration interface: USB Device, USB Host, LAN (HDM3065B) , GPIB (HDM3065H) .
Product types choosing
Model HDM3065 HDM3065B HDM3065H Resolution bits 6 1/2 6 1/2 6 1/2 DCV basic precision 75ppm 75ppm 75ppm Max reading rate 30,000 rdgs/s 30,000 rdgs/s 30,000 rdgs/s Memorizer 10,000 readings 10,000 readings 10,000 readings Measure DCV,ACV 100mV to 1,000V 100mV to 1,000V 100mV to 1,000V DCI 100uA to 10A 100uA to 10A 100uA to 10A ACI 100uA to 10A 100uA to 10A 100uA to 10A 2 lines and 4 lines resistance 100Ω to 100MΩ 100Ω to 100MΩ 100Ω to 100MΩ Connectivity,diode With,5V With,5V With,5V Frequency,period 10Hz to 300kHz 10Hz to 300kHz 3Hz to 300kHz Temperature RTD100、 thermistor、 thermocouple
RTD100、 thermistor、 thermocouple
RTD/PT100、 thermistor、 thermocouple
thermocouple Capacitance 1.0nF to 100.0uF 1.0nF to 100.0uF 1.0nF to 100.0uF Double row display Yes Yes Yes Display screen Color .Graph Color .Graph Color .Graph Statistical graphics histogram、bar diagram、run chart histogram、bar diagram、 run chart
histogram、bar diagram、 run chart
Back panel input terminal With With With IO interface USB Yes Yes Yes 232/485 Yes Yes Yes LAN No Yes Yes GPIB No No Yes Range2 /frequency
DCvoltage24hours3
TCAL±1℃90days
TCAL±5℃1year
TCAL±5℃2years
TCAL±5℃temperature coefficient/℃ 4 100mV 0.0030+0.0030 0.0040+0.0035 0.0050+0.0035 0.0065+0.0035 0.0005+0.0005 1V 0.0020+0.0006 0.0030+0.0007 0.0040+0.0007 0.0055+0.0007 0.0005+0.0001 I0V 0.0015+0.0004 0.0020+0.0005 0.0035+0.0005 0.0050+0.0005 0.0005+0.0001 100V 0.0020+0.0006 0.0035+0.0006 0.0045+0.0006 0.0060+0.0006 0.0005+0.0001 1000V 0.0020+0.0006 0.0035+0.0010 0.0045+0.0010 0.0060+0.0010 0.0005+0.0001 True RMS AC voltage2,5,6
100mV、1V、10V、100V and 750V range5—10Hz 0.35+0.02 0.35+0.03 0.35+0.03 0.35+0.03 0.035+0.003 10Hz—20kHz 0.04+0.02 0.05+0.03 0.06+0.03 0.07+0.03 0.005+0.003 20—50kHz 0.10+0.04 0.11+0.05 0.12+0.05 0.13+0.05 0.011+0.005 50-100kHz 0.55+0.08 0.60+0.08 0.60+0.08 0.60+0.08 0.060+0.008 100—300kHz 4.00+0.50 4.00+0.50 4.00+0.50 4.00+0.50 0.200+0.020 Resistance7 Testing current 100Ω 1mA 0.0030+0.0030 0.008+0.004 0.010+0.004 0.012+0.004 0.0006+0.0005 1kΩ 1mA 0.0020+0.0005 0.008+0.001 0.010?0.001 0.012+0.001 0.0006+0.0001 10kΩ 100μA 0.0020+0.0005 0.008+0.001 0.010+0.001 0.012+0.001 0.0006+0.0001 100kΩ 10μA 0.0020+0.0005 0.008+0.001 0.010+0.001 0.012+0.001 0.0006+0.0001 1MΩ 5μA 0.002+0.001 0.008+0.001 0.010+0.001 0.012+0.001 0.0010+0.0002 10MΩ 500nA 0.015+0.001 0.020+0.001 0.040+0.001 0.060+0.001 0.0030+0.0004 100MΩ 500nA‖
10MΩ0.300+0.010 0.800+0.010 0.800+0.010 0.800+0.010 0.1500+0.0002 DCcurrent potential drop of internal resistance 100μA <0.11V 0.010+0.020 0.040+0.025 0.050+0.025 0.060+0.025 0.0020+0.0030 1mA <0.11V 0.007+0.006 0.030+0.006 0.050+0.006 0.060?0.006 0.0020+0.0005 10mA <0.05V 0.007+0.020 0.030+0.020 0.050+0.020 0.060+0.020 0.0020+0.0020 100mA <0.5V 0.010+0.004 0.030+0.005 0.050+0.005 0.060+0.005 0.0020+0.0005 1A <0.7V 0.050+0.006 0.080+0.010 0.100+0.010 0.120+0.010 0.0050+0.0010 3A <2.0V 0.180+0.020 0.200+0.020 0.200+0.020 0.230+0.020 0.0050+0.0020 10A8 <0.5V 0.050+0.010 0.120+0.010 0.120+0.010 0.150+0.010 0.0050+0.0010 Capacitance15 1.0000nF 0.50+0.50 0.50+0.50 0.50+0.50 0.50+0.50 0.05+0.05 10.000nF 0.40+0.10 0.40+0.10 0.40+0.10 0.40+0.10 0.05+0.01 100.00nF 0.40+0.10 0.40+0.10 0.40+0.10 0.40+0.10 0.05+0.01 1.0000μF 0.40+0.10 0.40+0.10 0.40+0.10 0.40+0.10 0.05+0.01 10.000μF 0.40+0.10 0.40+0.10 0.40+0.10 0.40+0.10 0.05+0.01 100.00μF 0.40+0.10 0.40+0.10 0.40+0.10 0.40+0.10 0.05+0.01 range2/frequency 24hours3
TCAL±1℃90days
TCAL±5℃1year
TCAL±5℃2years
TCAL±5℃temperature coefficient/℃4 True RMS AC current2,6,9 potentia drop of internal resistance 100μA、1mA、10mA and 100mA range <0.011,<0.11, <0.05,<0.5V 3Hz-5kHz 0.10+0.04 0.10+0.04 0.10+0.04 0.10+0.04 0.015+0.006 5-10kHz
(typicalvalue)0.10+0.04 0.10+0.04 0.10+0.04 0.10+0.04 0.030+0.006 1Arange <0.7V 3Hz-5kHz 0.10+0.04 0.10+0.04 0.10+0.04 0.10+0.04 0.015+0.006 5-10kHz(typicalvalue) 0.10+0.04 0.10+0.04 0.10+0.04 0.10+0.04 0.030+0.006 3Arange <2.0V 3Hz-5kHz 0.23+0.04 0.23+0.04 0.23+0.04 0.23+0.04 0.015+0.006 5-10kHz
(typicalvalue)0.23+0.04 0.23+0.04 0.23+0.04 0.23+0.04 0.030+0.006 10Arange8 <0.5V 3Hz-5kHz 0.15+0.04 0.15+0.04 0.15+0.04 0.15+0.04 0.015+0.006 5-10kHz(typicalvalue) 0.15+0.04 0.15+0.04 0.15+0.04 0.15+0.04 0.030+0.006 Connectivity 1kΩ 0.002+0.030 0.008+0.030 0.010+0.030 0.012+0.030 0.0010+0.0020 DiodeTesting10 5V 0.002+0.030 0.008+0.030 0.010+0.030 0.012+0.030 0.0010+0.0020 DCrate(typicalvalue) (Normalize precision input)+(Normalize reference accuracy) Temperature11 PT100 (DIN/IEC751) Theprobe accuracy+0.05℃ 5kΩ thermistor Theprobe accuracy+0.1℃ Frequency:Technical Indicator±(%reading)12.13
100mV、1V、10、100V and 750 V range 143-10Hz 0.1 0.1 0.1 0.1 0.1 10-100Hz 0.03 0.03 0.03 0.03 0.035 100Hz-1kHz 0 0.008 0.01 0.01 0.015 1-300kHz 0.002 0.006 0.01 0.01 0.015 Square wave15 0.001 0.006 0.01 0.01 0.015 Extra Gate timeerror ± (%reading)13 Frequency 1second 0.1second 0.01second 3-40Hz 0 0.2 0.2 40-100Hz 0 0.06 0.2 100Hz-1kHz 0 0.02 0.2 1-300kHz 0 0.004 0.03 Square wave15 0 0 0 1.For DC:technical indicators are valid after 60 minutes of preheating, set to 10 or 100NPLC in the integral period, and enable automatic zero setting.For AC:technical indicators are effective when preheating for 60 minutes, using slow ac filter and sine wave
2.All ranges have 20% overrange except for 1,000DCV、750ACV、10ADC、3AAC、10AAC and diode testing.
3.Relative to the calibration standard
4.Outside of the range of TCAL±5℃,each degree(℃) increases a coefficient.
5.Technical indicators arei valid when sinusoidal wave is input >1.5% range and >1mVrms.The 750ACV range is limited to 8× 107v-hz.
6.Low frequency performance:three filter Settings are provided:3Hz、20Hz、200Hz.The frequency beyond the filter setting has been specified, no additional errors will occur.
7.Technical indicators are suitable for 4 lines or 2 lines measurement(peration bias returns to zero)resistance measurement.If there is no mathematical null, 2 lines resistance measurement will increase 0.2 Ω additional error.
8.The 10A range is provided on the front connector only.Each amplifier adds a 2mA base current value, or input current >5Arms.
9.Technical indicators are valid when sine wave is input >1.5% range and >10μAAC.
10.Technical indicators are suitable for the voltage measured at the input end.1mA test current is typical.The change of current source will lead to the change of voltage drop of diode junction
11.The selected probe limits the actual measuring range and measurement errors.Probe accuracy has included all measurement and ITS-90 temperature conversion errors.PT100Ro can be set to 100Ω±5Ω, to eliminate the original probe error.
12.Unless otherwise indicated, the technical indicators are valid after 60 minutes of warm-up and with sinusoidal input.Technical indicators are suitable for 1s gate time.(7 bits)
13.Suitable for sinusoidal and square wave input ≥100mV.For 10mV to 100mV inputs, multiply the reading error % by 10.
14.The range is 10% to 120% below 750ACV.
15.The square wave input is specified as 10Hz-300kHz.