The Hioki SM Series Super Megohm Meters are high resistance and ultra low current inspection devices with a 0.1 fA resolution to offer precise testing on production lines. To accommodate vehicle components with increasingly high breakdown voltages, the SM7120 is the first insulation tester in the world to be able to output a measurement voltage of 2000 V.
Key Features
• 300 times better noise resistance
• Max. 2000 V output : SM7120
• Max. 2 × 10^19 Ω display • Min. 0.1 fA resolution
• Built-in EXT I/O, RS-232C, GP-IB and USB
• Flexible, Multipurpose Design, High Resistance Meter/Electrometer/Picoammeter/IR Meter
• Measure resistance of materials by combining with optional electrode
Flexible, Multipurpose Design SUPER MEGOHM METER
Includes all of the following functions: • Electrometer • Picoammeter • IR Meter
2000V / 2*10^19 Ω Display
Perfect for EVs and other high-voltage applications Improved high voltage resistance and isolation performance in components are essential to meet the demands for high efficiency in recent years for applications such as automotive parts and wearable devices.
1/60 Variability, 300x Noise Resistance
Stability (repeatability) against power supply noise and external noise has improved dramatically due to a combination of new Super Megohm floating circuitry and triaxial connectors. Variability in normal usage environments is reduced to 1/60 compared to previous models, and to 1/300* in conditions where 50 V noise is applied.
Min. 6.4 ms High-Speed Inspection
6.4 ms = 4.1 ms measurement + 2.3 ms contact check Achieve high-speed measurement with an inspection time (from TRIG input to INDEX output) of 6.4 ms when contact checks that are essential for mass production inspections are included, and 7.0 ms when comparator measurement is included.
High-Performance Contact Checks
[Low capacity contact checks]
The SM7110/SM7120 is equipped with contact checks that can identify low-capacity capacitors of only a few pF as well as measured objects with a small capacitance. (Reference value: 0.1 pF to 99.99 pF)
[2-band selection]
As with battery production lines, select the frequency for contact checks to prevent the minute check signals on site with multiple various measuring instruments from getting crossed. These two contact checks can also be used in picoammeter mode with an external power supply. These are high-performance contact checks that prevent unnecessary retries and excess detection due to the effects of an external power supply, and that also prevent takt reduction and worsening yield ratio.
Electrodes for a Variety of Materials and Uses
• Electronic components
• Liquid
• Carpeting
• Processed rubber
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Number of channels | 1 ch |
---|---|
DC current measurement | 20 pA range (0.1 fA resolution), Accuracy: ±(2.0 % of rdg. +30 dgt.) 200 pA range (1.0 fA resolution), Accuracy: ±(1.0 % of rdg. +30 dgt.) 2 nA range (10 fA resolution), Accuracy: ±(0.5 % of rdg. +20 dgt.) 20 nA range (100 fA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.) 200 nA range (1 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.) 2 μA range (10 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.) 20 μA range (100 pA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.) 200 μA range (1 nA resolution), Accuracy: ±(0.5 % of rdg. +10 dgt.) *2 mA range (1 nA resolution), Accuracy: ±(0.5 % of rdg. +30 dgt.) (1) Measurement speed SLOW2 (internal integration time 13PLC) (2) At a temperature of 23 °C ±5 °C with humidity of 85% rh (3) 2 mA range (Measurement speed FAST only) |
Resistance measurement capabilities | 50 Ω to 2 × 10 ^19 Ω Note: Resistance measurement accuracy is defined by the current range accuracy and voltage setting accuracy. |
Setting voltage range (Accuracy) | 0.1 to 100.0 V, 100 mV resolution, Accuracy: ±0.1 % of setting ±0.05% f.s. 100.1 to 1000 V, 1 V resolution, Accuracy: ±0.1 % of setting ±0.05% f.s. |
[SM7120 only] 1000 to 2000 V,1 V resolution, Accuracy: ±0.2 % of setting ±0.10% f.s. | |
Current Limiter | 0.1 to 250.0 V: 5/ 10/ 50 mA, 251 to 1000 V: 5/ 10 mA, to 2000 V:1.8 mA |
Measurement time setting | Delay: 0 to 9,999 ms |
Functions | Comparator, averaging, self-calibration, jig Capacity open correction, cable length correction, surface resistivity, volume resistivity, voltage monitor, contact check |
Program function | 10 types of discharge, charge, measure and measurement sequence discharge patterns can be programmed. |
Display | LCD (8 lines of 30 characters), with backlight, High voltage warning indicator |
Interfaces | USB, RS-232C, GP-IB, EXT I/O (NPN/PNP can be switched) |
Power supply | 100 to 240V AC , 50/60 Hz, 45 VA |
Dimensions and mass | 330 mm (12.99 in)W × 80 mm (3.15 in)H × 450 mm (17.72 in)D, 5.9 kg (208.1 oz) |
Accessories | Power cord ×1, Instruction manual ×1, CD-R (Communications command instruction manual, USB driver) ×1, EXT I/O male connector ×1, Short plug ×1 |