- The mV600 controllers have been engineered with a number of outstanding features to meet all of your process control needs. mV600 offer a multitude of possibilities from ON/OFF or proportional dosage to analog recorder output and alarm. A host of self-testing features and user-friendly functions make mV600 a great value.
- Accurate, reliable and simple to install.
- Fully programmable microprocessor memory.
- Wiring the controllers is simple with extractable terminal modules
- The product is a real time microprocessor-based ORPcontroller. It provides accurate measurements, flexible ON/OFF or proportional control capabilities.
- mV600 Series ORP Controller’s FEATURES/BENEFITS:
- Display
- Large LCD with 4 ½ 17 mm digits and 3 ½ 10 mm digits.
- Fail Safe Alarm System
- Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.
- Differential Input
- In a system with poor grounding, it is possible to have a ground current flowing through the reference junction. This can cause a rapid degradation of the electrode. The Hanna differential input reduces the likelihood of ground loops.
- Proportional Control
- Slows the pump down when the measured ORP level approaches the set value, which ensures precise dosage and avoids costly waste of chemicals due to overdosage.
- Analog Output
- To enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a hard copy of the results on demand.
- PC Connectivity
- RS232C port allows for connection to a PC. Data transmission from the instrument to the PC is possible with the HI 92500 Windows® compatible application software offered by Hanna Instruments.
- Custom Programs
- Hi-tech microprocessor puts a host of variables at your disposal to fine tune your process, save on chemicals and meet regulatory requirements.
- Good Laboratory Practice (GLP)
- calibration date andtime and the mV calibration points used
- Relays
- 1 or 2 output relays for low conductivity or highconductivity dosage (COM, NO and NC contacts) and 1output relay for alarm condition (COM, NO and NC con-tacts)
- Calibration
- Automatic 1 or 2 points at 0, 350 and 1900 mV.
- Input
- ORP electrode with BNC connector.