Description
The V510i XL AOI system is a next generation solution for the SMT line, offering the powerful 3D inspection capabilities.
Specification
System | V510i XL | |
System Performances | ||
Inspection Functions | Missing, Offset, Skewed, Polarity, Billboard, Tombstone, Lifted/Bent Leads, Excess/Insufficient Solder, Overturn, Bridging, Wrong Part (OCV Marking), Pin Through Hole (Solderability & Pin Detection), Package Coplanarity, Lifted Lead (Height Measurement), Foreign Material Detection, Polarity Dimple Measurement | |
Board & Component Level Tracebility | Camera-Read Barcodes; External Barcode Reader Configured; OCR Capability with Batch Code Logging | |
System Hardware | ||
Operating System | Windows 10 Pro (64 bit) | |
Camera & FOV Size | 12MP CoaXPress Camera 60×45 mm @ 15um resolution | |
Optical Resolution | Default: 15um telecentric lens* Option: 13um telecentric lens* Option: 8um telecentric lens* | |
Inspection Speed | 4MP @ 20μm resolution: 22-37cm²/sec 12MP @ 15μm resolution: 45-60cm²/sec | |
3D Technologies | Phase Shift Profilometry’s (PSP) Methodology with 4-way projectors | |
Lighting Module | Concurrent Lighting Module | |
X-Y Gantry System | Gantry Robot Systems with Linear Motor and Optical Linear Encoders | |
Conveyor Width Adjustment | Auto Width Adjustment; Bottom-Up Clamping; In-line SMEMA | |
PCB Dimension | Standard | FDL |
Maximum PCB Size (L x W) | 460mmx690mm (18.1”x27.1”) | DL Equal: 460mmx325mm (18.1”x12.7”) Single Lane: 460mmx600mm (18.1”x23.6”) |
Minimum PCB Size (L x W) | 50mmx50mm (2”x2”) | 50mmx50mm (2”x2”) |
Maximum PCB Inspectable Area (L x W) | 460mmx683mm (18.1”x26.8”) | DL Equal: 460mmx318mm (18.1”x12.5”) Single Lane: 460mmx593mm (18.1”x23.3”) |
Maximum PCB Thickness | 7mm (0.27″) | 7mm (0.27″) |
Minimum PCB Thickness | 0.5mm (0.02″) | 0.5mm (0.02″) |
Maximum PCB Weight | 3kg | 3kg |
Top Clearance of PCB | 50mm | 50mm |
Bottom Clearance of PCB | 100mm | 100mm |
PCB Edge Clearance | 3.5mm | 3.5mm |
PCB Transport Height | 875mm – 965mm | 875mm – 965mm |
PCB Temperature | Ambient operating temperature is ~5⁰C to 40⁰C, maximum PCB temperature 80⁰C. | |
Power and Environmental | ||
Power Supplies | 100-120 V, 16A / 200-240V, 8A Single Phase | |
Air requirement | 0.6 Mpa/85 psi | |
System footprint (Width X Depth X Height) | 1060mm x 1440mm x 2116mm | |
Total system weight | 960kgs |