Brief introduction
– UC2518X can be used to coil, inductor, transformer, coil, the relay contact resistance, resistance, resistance of fuse connector, cable, printed circuit board line resistance, resistance welding holes, conductive film, metal detection etc.. The function of temperature compensation to eliminate theinfluence of temperature on the test, temperature conversion function can be effectively measured the temperature measuring. UC2518X is a lowresistance tester for high speed, high precision, high performance, can meet the quality control on production line, incoming inspection and lab measurement, also suitable for automation testing.
Features:
– 4.3 inches TFT LCD display, resolution of 480 * 272 RGB
– U disk directly save the test results, more convenient
– the highest resistance accuracy 0.05%
– built in the comparator, HI, LO, IN separation
– the function of temperature compensation, temperature conversionfunction
The temperature of 0.1 DEG C – basic accuracy
In statistics, CpK, Cp and other statistics
– internal 100 set file or call, U disk can be extended more than 500 sets of test file or call
– by USB HOST to realize the instrument software version upgrade and update
– U disk support FAT16 format, FAT32 file system
In standard HANDLER, USB HOST, USBCDC, USBTMC, RS232C, optionalGPIB interface.
Measurement precision and function | |
R basic precision | 0.05% + 2 word (2 M Ω range is 0.2%, to 10 M Ω range of 0.3%) |
Measurement speed | Power frequency 50 hz, fast: 22, ms medium speed: 42 ms, slow: 102 ms, rapid 2:7 ms; 60 hz power supply, fast: 18.5 ms, medium speed: 35 ms, slow: 102 ms, rapid 2:7 ms; To show the above closing speed.When the show opened, plus 10 ms show time. |
statistics | The CpK and Cp and other statistics |
Range way | Automatic, maintain, manual selection |
triggered | The external ,internal |
The average number of | 1—255 |
Delay time | 0-9999 ms to 1 ms step by step |
The calibration function | Short circuit zero, zero, load calibration |
Testing the configuration | Four terminal |
Display mode | Direct reading, Δ % |
Range and the test current | |
UC2518A (10μΩ~200kΩ) | 200 mΩ(100mA):10μΩ~200 mΩ 2Ω(100mA) :200mΩ~2Ω 20Ω(10mA) :2Ω~20Ω 200Ω(1mA) :20Ω~200Ω 2kΩ(100μA) :200Ω~2kΩ 20kΩ(100μA) :2kΩ~20kΩ 200kΩ(10μA) :20kΩ~200kΩ |
The comparator | |
sorting | HI、LO、IN |
Temperature measurement | |
Basic precision | 0.1℃ |
Measuring time | 100±10ms |
The temperature sensor | Pt, measurement range 10.0 ℃ to 99.9 ℃ |
Analog input: 0 ~ 2 v, 99.9 ℃ to 999.9 ℃ | |
Temperature compensation function | When converted to set temperature resistance |
Temperature conversion function | Resistance change into temperature change |
other | |
display | 24 true color, resolution of 480 x 272 TFT LCD |
memory | More than 100 groups of internal storage, U disk more than 500 groups |
interface | The standard HANDLER, USB HOST, USBCDC USBTMC, optional GPIB, RS232C interface |