Description
FTP series programmable DC power supply provides wide range voltage / current output and automatic constant power function, which greatly increases the application coverage, avoiding the need for multiple power supplies, saves a lot cost for users. Accurate output (voltage: 0.1%+0.1%F.S.; current: 0.1%+0.2%F.S.), fast response (1ms typical) and low ripple noise (Vrms 0.02%F.S. typical) have always been the heritage of Faith Power. For bench top applications, this series provides an intuitive user interface with full keypad and rotary knob. System integrators benefit from the standard USB (virtual SERIAL) and LAN interfaces supporting both SCPI commands and ModBus RTU protocol. Application control software, programming manual and a complete set of development DLLs are available to reduce programming time and increase productivity. The application software allows users to control the power supply, execute test sequences, or log measurements
Feature
■ Output voltages: 0 V…40 V up to 0 V… 1500 V;
■ Output current: 0 A…3.5 A up to 0 A… 240 A;
■ Output power: 2 / 3.2 / 6.5 kW;
■ CV, CC, CP operation modes;
■ Easy Master-Slave parallel or serial;
■ Precision V & I measurement;
■ High speed programming;
■ 1ms typical transient response;
■ Programmable sequence;
■ Voltage & current slew rate control;
■ CV / CC priority;
■ Foldback protection;
■ Wide operating region for output;
■ Automotive waveform test feature, compatible with ISO16750-2, VW80000 standards *1
■ Remote sense compensation;
■ Optional analog programming & monitoring interface;
■ ±OVP, ±OCP, ±OPP, OTP, ±LVP;
■ Voltage limit, current limit;
■ Standard LAN, USB (serial), optional GPIB interface;
■ SCPI and ModBus RTU protocol;
■ TFT color LCD display.
Specification
Specification table 1 | ||||||
Model | FTP020-40-120 | FTP020-50-110 | FTP020-80-60 | FTP020-120-40 | FTP020-160-30 | FTP020-300-16 |
Voltage | 0~40V | 0~50V | 0~80V | 0~120V | 0~160V | 0~300V |
Current | 0~120A | 0~110A | 0~60A | 0~40A | 0~30A | 0~16A |
Power | 2000W | |||||
Model | FTP032-40-120 | FTP032-50-110 | FTP032-80-60 | FTP032-120-40 | FTP032-160-30 | FTP032-300-16 |
Voltage | 0~40V | 0~50V | 0~80V | 0~120V | 0~160V | 0~300V |
Current | 0~120A | 0~110A | 0~60A | 0~40A | 0~30A | 0~16A |
Power | 3200W | |||||
Model | FTP065-40-240 | FTP065-50-220 | FTP065-80-120 | FTP065-120-80 | FTP065-160-60 | FTP065-300-32 |
Voltage | 0~40V | 0~50V | 0~80V | 0~120V | 0~160V | 0~300V |
Current | 0~240A | 0~220A | 0~120A | 0~80A | 0~60A | 0~32A |
Power | 6500W | |||||
Voltage programming | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.1%F.S. | |||||
Current programming | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.3%F.S. | 0.1%+0.2% F.S. | ||||
External analog programming | ||||||
Control voltage | 0~5V or 0~10V corresponds to 0~100%F.S. | |||||
Voltage accuracy | 0.2%F.S. | |||||
Current accuracy | 0.5%F.S. | |||||
Analog output | ||||||
Output voltage | 0~100%F.S. corresponds to 0~10V. | |||||
Voltage accuracy | 0.5%F.S. | |||||
Current accuracy | 0.5%F.S. | |||||
Line regulation | ||||||
Voltage | 0.01%+0.01%F.S. | |||||
Current | 0.02%+0.01%F.S. | |||||
Load regulation | ||||||
Voltage | 0.01%+0.05%F.S. | 0.01%+0.01%F.S. | ||||
Current | 0.02%+0.1%F.S. | |||||
Voltage measurement | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.1%F.S. | |||||
Current measurement | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.3%F.S. | 0.1%+0.2%F.S. | ||||
Ripple noise | ||||||
Ripple Vpp | 60mV | 70mV | 80mV | 80mV | 100mV | 100mV |
Ripple Vrms | 20mV | 20mV | 20mV | 20mV | 40mV | 40mV |
Rise slew rate | ||||||
Voltage | 5V/ms(max) | |||||
Current | 2A/ms(max) | |||||
OVP Setting | ||||||
Range | 0~110%F.S. | |||||
Accuracy | 1%F.S. | |||||
Transient | Typical 1ms | |||||
Efficiency | 0.9(Typical) | |||||
Parallel/Serial | Support master-slave parallel and serial operation | |||||
Communication | RS232 and LAN | |||||
AC input | 190VAC~265VAC, 47Hz~63Hz, PF: 0.98(Typical) | |||||
Operation temp | 0℃~40℃ | |||||
Storage temp | -20℃~70℃ | |||||
Altitude | <2000m | |||||
Dimension | 430(W)×88(H)×453(D)mm (2kW&3.2kW model); 430(W)×177(H)×503(D)mm (6.5kW model) | |||||
Weight | 15kg(2kW&3.2kW model); 29kg(6.5kW model) |
Specification table 2 | ||||||
Model | FTP020-400-12 | FTP020-600-8 | FTP020-800-8 | FTP020-1000-5 | FTP020-1200-5 | FTP020-1500-3.5 |
Voltage | 0~400V | 0~600V | 0~800V | 0~1000V | 0~1200V | 0~1500V |
Current | 0~12A | 0~8A | 0~8A | 0~5A | 0~5A | 0~3.5A |
Power | 2000W | |||||
Model | FTP032-400-12 | FTP032-600-8 | FTP032-800-8 | FTP032-1000-5 | FTP032-1200-5 | FTP032-1500-3.5 |
Voltage | 0~400V | 0~600V | 0~800V | 0~1000V | 0~1200V | 0~1500V |
Current | 0~12A | 0~8A | 0~8A | 0~5A | 0~5A | 0~3.5A |
Power | 3200W | |||||
Model | FTP065-400-24 | FTP065-600-16 | FTP065-800-16 | FTP065-1000-10 | FTP065-1200-10 | FTP065-1500-7 |
Voltage | 0~400V | 0~600V | 0~800V | 0~1000V | 0~1200V | 0~1500V |
Current | 0~24A | 0~16A | 0~16A | 0~10A | 0~10A | 0~7A |
Power | 6500W | |||||
Voltage programming | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.1%F.S. | |||||
Current programming | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.2% F.S. | |||||
External analog programming | ||||||
Control voltage | 0~5V or 0~10V corresponds to 0~100%F.S. | |||||
Voltage accuracy | 0.2%F.S. | |||||
Current accuracy | 0.5%F.S. | |||||
Analog output | ||||||
Output voltage | 0~100%F.S. corresponds to 0~10V. | |||||
Voltage accuracy | 0.5%F.S. | |||||
Current accuracy | 0.5%F.S. | |||||
Line regulation | ||||||
Voltage | 0.01%+0.01%F.S. | |||||
Current | 0.02%+0.01%F.S. | |||||
Load regulation | ||||||
Voltage | 0.01%+0.01%F.S. | |||||
Current | 0.02%+0.1%F.S. | |||||
Voltage measurement | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.1%F.S. | |||||
Current measurement | ||||||
Resolution | 16Bits | |||||
Accuracy | 0.1%+0.2%F.S. | |||||
Ripple noise | ||||||
Ripple Vpp | 300mV | 300mV | 500mV | 450mV | 500mV | 700mV |
Ripple Vrms | 60mV | 60mV | 80mV | 80mV | 120mV | 150mV |
Rise slew rate | ||||||
Voltage | 5V/ms(max) | |||||
Current | 2A/ms(max) | |||||
OVP Setting | ||||||
Range | 0~110%F.S. | |||||
Accuracy | 1%F.S. | |||||
Transient | Typical 1ms | |||||
Efficiency | 0.9(Typical) | |||||
Parallel/Serial | Support master-slave parallel and serial operation | |||||
Communication | RS232 and LAN | |||||
AC input | 190VAC~265VAC, 47Hz~63Hz, PF: 0.98(Typical) | |||||
Operation temp | 0℃~40℃ | |||||
Storage temp | -20℃~70℃ | |||||
Altitude | <2000m | |||||
Dimension | 430(W)×88(H)×453(D)mm(2kW&3.2kW model); 430(W)×177(H)×503(D)mm(6.5kW model) | |||||