Cable design
Construction | Material | Detail | Diameter |
---|---|---|---|
Center conductor | Copper, Silver plated | Wire | 1.4 mm |
Dielectric | SPE (Foamed Polyethylene) | 3.8 mm | |
Outer conductor | Aluminum / PES | Longitudinal Foil, 100% Coverage | 4.0 mm |
Outer conductor | Copper, Tin plated | Braid, 87% Coverage | 4.5 mm |
Jacket | PUR (Polyurethane) | RAL 9005 – bk | 5.3 mm ±0.2 |
Electrical data
Mechanical data
Environmental data
Nominal attenuation and power
Frequency (GHz) | Attenuation * (dB/m) | Attenuation * (dB/ft) | CW Power ** (W) |
---|---|---|---|
0.01 | 0.020 | 0.006 | 1200 |
0.05 | 0.046 | 0.014 | 537 |
0.10 | 0.067 | 0.020 | 379 |
0.15 | 0.083 | 0.025 | 310 |
0.20 | 0.097 | 0.030 | 268 |
0.25 | 0.110 | 0.034 | 240 |
0.30 | 0.121 | 0.037 | 219 |
0.45 | 0.152 | 0.047 | 179 |
0.50 | 0.162 | 0.049 | 170 |
0.55 | 0.171 | 0.052 | 162 |
0.60 | 0.180 | 0.055 | 155 |
0.65 | 0.188 | 0.057 | 149 |
0.70 | 0.196 | 0.060 | 143 |
0.75 | 0.204 | 0.062 | 139 |
0.80 | 0.212 | 0.065 | 134 |
0.85 | 0.220 | 0.067 | 130 |
0.90 | 0.227 | 0.069 | 126 |
0.95 | 0.235 | 0.072 | 123 |
1.00 | 0.242 | 0.074 | 120 |
1.50 | 0.309 | 0.094 | 98 |
2.00 | 0.369 | 0.112 | 85 |
2.50 | 0.424 | 0.129 | 76 |
3.00 | 0.476 | 0.145 | 69 |
3.50 | 0.526 | 0.160 | 64 |
4.00 | 0.574 | 0.175 | 60 |
4.50 | 0.620 | 0.189 | 57 |
5.00 | 0.666 | 0.203 | 54 |
6.00 | 0.753 | 0.229 | 49 |
7.00 | 0.836 | 0.255 | 45 |
8.00 | 0.917 | 0.280 | 42 |
9.00 | 0.996 | 0.304 | 40 |
10.00 | 1.073 | 0.327 | 38 |
11.00 | 1.148 | 0.350 | 36 |
12.00 | 1.222 | 0.373 | 35 |
13.00 | 1.295 | 0.395 | 33 |
14.00 | 1.367 | 0.417 | 32 |
15.00 | 1.438 | 0.438 | 31 |
16.00 | 1.508 | 0.460 | 30 |
17.00 | 1.577 | 0.481 | 29 |
18.00 | 1.646 | 0.502 | 28 |