Current range | 0.1A~10A | 10A~200A | 200A~1200A |
Attenuation ratio | 100mV AC/A AC | 10mV AC/A AC | 1mV AC/A AC |
Accuracy | ≤3%+10mV | ≤2%+5mV | ≤1%+1mV |
Measurement condition | Measure condition:23℃±3℃,20~75%RH,Sinusoidal frequency 48Hz~65Hz,distortion <1%, No dc component,External magnetic field <40A/m, No ac magnetic field, the center of the test sample, load impedance≥1MΩand ≤47pF | ||
Bandwidth | 10Hz~100kHz(-3dB) | ||
Max. dV/dt | 10A/μs | ||
Max. current | when <1kHz,1000A Continuous current ,1200A(about forty minutes in the maximum )(if the measuring time over twenty minutes ,it should be stopped) | ||
Load impedance | ≥1MΩ and ≤47pF | ||
Rise/Fall time | ≤40us | ||
Working voltage | 600V rms | ||
Common mode voltage | 600V CAT III | ||
Stack DC current influence | ≤30A DC, | ||
Max. Jaw opening diameter | 53mm | ||
Max. Conductor size | Cable:max. Diameter:Ф52mm;Total wiring harness;single:5х5mm,Four bus wiring harness:30х5mm | ||
Size | 216х111х45mm | ||
Weight | 500g |