Brief Introduction
■ TH9310/20 series withstanding voltage/insulation resistance tester is an economical and intelligent safety tester with the characteristics of small size, light weight, pleasing appearance and easy operation. TH9310/20 series can be widely used in the safety tests of household appliances, transformer, electrical equipments and components.
Application
Technical Parameter
Model | TH9310/20 | TH9310B | ||
Withstanding Voltage Test | ||||
Output Voltage | AC | 0.05 —5.00kV ± (2% reading+5digits), (50Hz、60Hz optional) | ||
DC | 0.05 —6.00kV ± (2% reading+5digits) | —— | ||
Voltage Adjustment Rate | ≤ (1% – 5V)(rated power) | |||
Current TestRange | AC | TH9310:0.000mA – 10.00mA ± (2% reading+2digits)TH9320:0.000mA – 20.00mA ± (2% reading+2digits) | ||
DC | TH9310:0uA – 5.00mA ± (2% reading+2digits)TH9320:0uA –10.00mA ± (2% reading+2digits) | —— | ||
Discharge Function | Discharge after test ends(DCW) | |||
Insulation Resistance Test | ||||
Output Voltage | 0.10kV – 1.00kV ± (2%reading+2V) | —— | ||
Resistance Test Range | 1MΩ– 9999MΩ | —— | ||
Resistance Test Accuracy | 500V-1000V | 1MΩ– 1000MΩ ± (5%reading+2digits)1000MΩ–9999MΩ ± (10%reading+2digits) | —— | |
100V-500V | 1MΩ– 1000MΩ ± (10%reading+2digits) | —— | ||
Discharge Function | Discharge after test ends | —— | ||
Arc Detection | ||||
Measurement Range | AC | 1 – 9 levels (factory default 5)(20mA,18mA, 16mA, 14mA, 12mA, 10mA, 7.7mA, 5.5mA, 2.8mA respectively) | ||
DC | 1 – 9 levels | —— | ||
General Specification | ||||
Memory | 5 groups | |||
Voltage Rising Time | 0.1s – 999.9s | |||
Test Time Setting(AC/DC) | 0.2s – 999.9s | |||
Waiting Time(IR) | 0.2s – 999.9s | —— | ||
Time Accuracy | ±(1%+0.1s) | |||
Dimension(W×H×D) | 280mm×89mm×428mm/10kg | |||
Interface | ||||
Standard | HANDLER, RS232, USBDRV(PC interface), USBHOST(USB port) |
Accessary
Standard | |||||
Accessories name | Model | ||||
High voltage test cable (red) | TH90003R | ||||
High voltage test cable | TH90003C |