Descriptions
6355/6356+6243H/6243/6223 provide a frequency response range of 100Hz to 200k/500kHz and a maximum output current of 640A/320A/120A. These systems are used for testing inductors, coils, ferrites, and core saturation currents.
Features
- Frequency Response 100Hz-200k/500kHz
- Supports maximum output DC bias current of 640A/320A/120A
- DCR measurement function
- Can sustain maximum power output for long periods of time
- Output impedance: 100Ω
- Open/short circuit calibration function
- Supports meter measurement mode/multi-step list testing
6350+ Series | ||||||
Model | 6355+ 6243H/6243/62236356+ 6243H/6243/6223 | |||||
Frequency Response | 100Hz-200kHz (6355+ 6243H/6243/6223)100Hz-500kHz (6356+ 6243H/6243/6223) | |||||
DC Bias Current Max. | 640A (6243H)320A (6243)120A (6223) | |||||
Power consumption Max. | 640W (6243H/6243)320W (6223) | |||||
Selection | ||||||
Model | 6355+6243H | 6355+6243 | 6355+6223 | 6356+6243H | 6356+6243 | 6356+6223 |
Frequency Response | 100Hz-200kHz | 100Hz-200kHz | 100Hz-200kHz | 100Hz-500kHz | 100Hz-500kHz | 100Hz-500kHz |
Output Current Max. | 640A | 320A | 120A | 640A | 320A | 120A |
Power consumption | 640W | 640W | 320W | 640W | 640W | 320W |
units of the DC Bias | 16 | 8 | 6 | 16 | 8 | 6 |
Output Current (unit) | 40A | 40A | 20A | 40A | 40A | 20A |
SPEC
Current Accuracy | 0.000A-1.000A 1%+5mA |
1.001A-5.000A 2% | |
5.001A-40.000A 3% | |
DCR Test | ● |
Constant power output | ● |
Current switch | ● |
6355/6356 LCR Meter
Model | 6355/6356 | |
Frequency Range | 10Hz-200kHz/10Hz-500kHz | |
Frequency Setting | Continuity | |
Frequency Output Accuracy | ±0.01% | |
Frequency Resolution | 5-bit Frequency | |
Basic Accuracy | ±0.05% | |
Drive Level | Test Signal Voltage Level | AC:10mV – 2Vrms DC:10mV – 2V |
Voltage Minimum Resolution | 1mV | |
Output Impedance | 100Ω | |
Measurement Mode | Meter mode, list mode | |
Measurement Parameters | |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C | |
Test Time (Fastest) | 8mS |
6355/6356 Measurement Parameters
Parameters | Range |
|Z|, R, X | 0.001mΩ~99.999MΩ |
|Y|, G, B | 0.1nS~99.999S |
Cs Cp | 0.01pF~9.9999F |
Ls Lp | 0.1nH~99.999kH |
D | 0.00001~9.9999 |
Q | 0.1~9999.9 |
DCR | 0.001mΩ~99.999MΩ |
Δ% | -9999%~999% |
θ | -180° ~+180° |
System
Measurement Circuit | Series/Parallel |
Correction | Open Circuit/Short Circuit |
List Mode | 8 steps |
Bulit-in Storge | 128 sets |
USB Host Storge | LCR setting documents, list mode setting document |
Trigger Test | Auto, manual, RS-232, GPIB, Handler |
Power Supply | Voltage:88~132Vac or 195~264Vac (Switchable) |
Frequency:47-63Hz | |
Power consumption | 300VA (6223)、600VA (6243H/6243) |
Environment | Temperature:10℃-40℃ |
Humidity:20-90%RH | |
Dimension | 358x148x343 mm (W*H*D) /6355 |
337×145×525mm (W*H*D) /6223 | |
435×145×644mm (W*H*D) /6243H/6243 | |
Weight | 3Kg (6355/6356) |
15Kg (6223) | |
20Kg (6243H/6243H/6243) | |
Display | Color Screen, 7″ TFT (800*480)|6355 |
Interface | RS-232、Handler |