- The AN97H series frequency conversion power supply adopts digital technology and IGBT intelligent output, pure output wave, with excellent technical performance. The power supply has an anti-shock circuit, suitable for various shock loads such as motors and air conditioners; excellent dynamic characteristics, strong load adaptation, high efficiency, simple operation, cost-efficient, suitable for industries such as export electrical appliances plants, laboratories, defense and military industries.
- Features
- Over shock capacity: impact load of 1/3 capacity of power supply directly without soft start.;
- Adjustable voltage and frequency during output status;
- Measurement: voltage, current, frequency, active power;
- Level of voltage: 1.0~150.0V, 150.1~300.0V automatically adjusted or locked to 1.0~300.0V;
- Line voltage drop compensation
- Shortcuts groups, power-off memory, shortcuts key;
- Lock key, user-friendly design to prevent mis-operation;
- HD VFD display;
- Standard RS232 port, optional RS485 port or remote control port.
- Applications
- Over shock capacity: impact load of 1/3 capacity of power supply directly without soft start
Model | AN97000H(F) | AN97001H(F) | AN97002H(F) | AN97003H(F) | AN97005H(F) | AN97010H(F) | AN97010TSH(F) | ||
---|---|---|---|---|---|---|---|---|---|
capacity | 500VA | 1kVA | 2kVA | 3kVA | 5kVA | 10kVA | 10kVA | ||
Input | Voltage,Frequency | Single-phase 2-wires + PE,Phase voltage: 220V±22V, 50/60Hz±5%Hz; An97010tsh is three-phase four wire + PE | |||||||
AC output | Voltage | Single-phase 2-wires;Automatic files: (low) 1.0 ~ 150.0V, (high-grade) 150.1~300V; high-grade lock:1.0 〜 300.0V | |||||||
Frequency | 45.0~65.0Hz,100Hz、120Hz、200Hz、240Hz、400Hz | ||||||||
Rated Current | 110V | 4.6A | 9.2A | 18.2A | 27.4A | 45.6A | 91.0A | 91.0A | |
220V | 2.3A | 4.6A | 9.1A | 13.7A | 22.8A | 45.5A | 45.5A | ||
Setting accuracy | Voltage | Resolution:0.1V,Accuracy:0.4%×reading value +0.1%×full scale value | |||||||
Frequency | Resolution:0.1Hz,Accuracy:0.1% | ||||||||
Testing Accuracy | Voltage | Resolution:0.1V,Accuracy:0.4%×reading value +0.1%×full scale value | |||||||
Frequency | Resolution:0.1Hz,Accuracy:0.1% | ||||||||
Current | Resolution:0.001A/0.01A,Accuracy:0.4%×reading value +0.1%×full scale value | ||||||||
Power | Resolution:0.1W/1W,Accuracy:5% | ||||||||
Frequency stability | ≤0.1% | ||||||||
Voltage distortion | Linear load:THD<1.5% | ||||||||
Transient recovery time | 20ms | ||||||||
Crest factor | 1.41±0.1 | ||||||||
Source voltage effect | ≤1% | ||||||||
Load effect | ≤1% | ||||||||
Over power | 105%<Output≤110% the output will be stopped within 15s ;110%<Output≤120% the output will be stopped within 5s; | ||||||||
Loading capacity | Can start a inductive load which capacity is less than 0.5 rated power capacity of AC power supply, or a rectifier load which crest factor is less than 3.0 | ||||||||
Protection mode | Short circuit protection, overload protection, power device overheat protection | ||||||||
Function | Display | VFD | |||||||
Online adjustment function | Output voltage and frequency can be adjusted online (45.0-65.0hz) | ||||||||
memory function | Power down memory function, memory last output mode and parameters;6 groups | ||||||||
Communication | RS232(standard)、RS485(options)、 Remote control port(options) | ||||||||
Environment | Temperature/humidity | 0~40℃,20~90%RH | |||||||
Dimension W×H×D(mm) | 483×200×380 ( The height does not include the machine foot, the machine foot is detachable, the height is 15mm)) | 483×555×400 | 483×755×400 | 483×905×600 | |||||
Weight (Kg) | 20 | 54 | 62 | 80 | 195 |