Electrical Specifications | |
AC Current | |
Range | 200.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ±5 digits (45 – 65 Hz) |
2.5 % ±5 digits (65 – 400 Hz) | |
Crest Factor | 2.5 @ 125 A |
1.55 @ 200 A | |
Add 2 % for C.F. >2 | |
DC Current | |
Range | 200.0 A |
Resolution | 0.1 A |
Accuracy | 2 % ±5 digits |
AC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1.5 % ±5 digits (45 – 400 Hz) |
DC Voltage | |
Range | 600.0 V |
Resolution | 0.1 V |
Accuracy | 1 % ±5 digits |
Resistance | |
Range | 600.0 Ω/6000 Ω |
Resolution | 0.1 Ω/1 Ω |
Accuracy | 1 % ±5 digits |
Mechanical Specifications | |
Size (L x W x H) | 225 x 65 x 46 mm |
225 x 65 x 46 mm | 275 g (including batteries) |
Jaw Opening | 18 mm |
Detachable Jaw Cable Length | 900 mm |
Environmental Specifications | |
Operating Temperature | -10 °C to +50 °C |
Storage Temp | -40 °C to +60 °C |
Operating Humidity | Non condensing (<10 °C) |
≤90 % RH (at 10 °C to 30 °C) | |
≤75 % RH (at 30 °C to 40 °C) | |
≤45 % RH (at 40 °C to 50 °C) | |
(Without Condensation) | |
Operating Altitude | 2000 meters |
Storage Altitude | 12,000 meters |
Temperature Coefficients | 0.1 x(specified accuracy)/ °C (<18 °C or > 28 °C) |
Safety Compliance | ANSI/ISA S82.02.01:2004 |
CAN/CSA-C22.2 No. 61010-1-04 | |
UL 61010-1:2004 | |
EN/IEC 61010-1:2001 to 600V CAT III | |
Pollution Degree 2 | |
Batteries | 2 AA, NEDA 15A, IEC LR6 |