Key Features:
Features:
- Easy-operation mode with automatic trace diagnostics, one-button setup and events detection;
- Markers for distance, attenuation, reflectance, and splice loss;
- Dynamic range up to 45dB;
- Event dead zone is less than 0.6m (Type III);
- Attenuation dead zone is less than 4m (Type III);
- The sampling points up to 256,000 (Type II & III);
- SR-4731.sor file formats;
- Support VFL;
- Support iOTA(Optional, for Type III only);
- Support power meter (Optional, +10 to -60 dBm);
- Support light source (Optional, Use OTDR port, 1310nm/1550nm, >-4dBm);
- Support 400X fiber optic microscope(Optional);
- Remote measurement via RJ45 connection using AITELONG OTDR Desktop software.
- Model Series:
Series Model Wavelength Dynamic Range Type Ⅰ 18EA-13F 1310/1550nm 28/26dB Type Ⅱ 18EA-13J 1310/1550nm 32/30dB 18EA-13M 1310/1550nm 35/34dB Type Ⅲ 18EA-13Mi 1310/1550nm 35/34dB 18EA-13Ri 1310/1550nm 40/39dB 18EA-13Ui 1310/1550nm 43/42dB 18EA-13Wi 1310/1550nm 45/43dB 18EA-123Qi 1310/1490/1550nm 39/37/37 dB 18EA-134Qi 1310/1550/1625nm 39/37/38dB 18EA-135Qi 1310/1550/1650nm 39/37/37 dB 18EA-1234Qi 1310/1490/1550/1625nm 39/37/37/38dB 18EA-1235Qi 1310/1490/1550/1650nm 39/37/38/37dB General Specification:
Screen 5.6 inch TFT touch screen USB
USB, type A port
Storage 16G
Size and Weight 161(H) x 210(W) x 46(D)mm; 1.0kg
Temperature Operating: -10°C to 50°C; Storage: -40°C to 70°C
Relative Humidity 0% to 95% (non-condensing)
Battery Rechargeable Li-Lon battery; Working time: 8 hours; Charging time: <3 hours
Power Supply Input: 100-240V AC, 50-60Hz, 2A; Output: 15V DC, 2A
Technical Specification:
Model Series Type Ⅰ Type Ⅱ Type Ⅲ Event Dead Zone Less than 5 m
Less than 1m
Less than 0.6 m
Attenuation Dead Zone Less than 15 m
Less than 5 m
Less than 4 m
Sampling Resolution 0.625 — 2.5m
0.125–1m
0.03 — 1m
Pulse Width 10,30,50,100,275,500,1000,
5000,10000 ns
3, 5, 10, 30, 50, 100, 275, 500, 1000,
5000, 10000, 20000 ns
Distance Range 0.5,2.5,5,15,40,80,120,160 km
0.5, 2.5, 5, 15, 40, 80, 120, 160, 200, 240 km
Sampling Points 87500
256000
Ethernet N/A
10/100M Base-T, RJ45
Linearity ±0.05 dB/dB
±0.03 dB/dB
IOR 1.30000 to 1.80000
Distance Uncertainty ±(0.75+0.0050%×distance + sampling resolution)
Measurement Time 5s to 180s, Real time
VFL Wavelength 650±20nm
Output Power +10dBm
Operation mode CW, 1Hz
Power Meter (Optional)
Wavelength 780 to 1800 nm
Calibrated wavelength 850, 1300, 1310, 1490, 1550, 1625 nm
Measurement range +10 to -60 dBm
Resolution 0.01 dB
Light Source (Optional)
Wavelength
1310/1550 ±20 nm
Output power >-4 dBm
Operation mode CW, 270Hz, 330Hz, 1KHz, 2kHz
Fiber Optic Microscope(Optional ) 400X
iOTA(Optional, for Type III only ) Intelligently combine different pulse width, one time get loss and return loss of fiber and splitter. Multiple pulse acquisitions and algorithms to deliver detail information of every element on the fiber link.
iNET(Optional) The iNET include PING, Trace Route, FTP upload and download, and HTTP features for Ethernet Link Fault check testing.