True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
Total harmonics distortion (THD), AC/DC voltage up to 600 V, AC current up to 1000 A, resistance, frequency, temperature
Peak hold
Optional PC interface capability (RS-232 KIT2)
Audible continuity
Auto power off
Automatic polarity
Low battery indication
Data hold
Large, easy to read LCD display with backlight
Accommodates conductors up to 1.77″ (45 mm) in diameter
Voltage overload protection for all functions up to 600 V AC/DC
Specifications
FEATURE | ACD-41PQ | ACD-45PQ |
True-rms | • | |
AC Current | 40.00 A, 400.0 A, 1000 A | 40.00 A, 400.0 A, 600 A |
AC/DC Voltage | 600.0 V | |
Resistance | 999.9 Ω | |
Continuity | • | |
Temperature | -58 °F → 572 °F (-50 °C → 300 °C) | – |
Frequency | 5.00 Hz → 500.0 Hz | |
Active power | (W) 0 kW → 600.0 kW | 0 kW → 360.0 kW |
Reactive power (VAR) | 0 kVAR → 600.0 kVAR | 0 kVAR → 360.0 kVAR |
Apparent power (VA) | 0 kVA → 600.0 kVA | 0 kVA → 360.0 kVA |
Power Factor | 0.10 → 0.99 | |
Energy (KWHr) | • | • |
Total Harmonic Distortion (THD%) | 0.0 % → 99 % | – |
Accommodates Conductors | up to 1.77″ (45 mm) in diameter | up to 1.02″ (26 mm) in diameter |
Specifications | |
TRMS | YES |
AC Current | 40.0 / 400.0 / 1000 A |
AC Current Basic Accuracy | +/-(1.0% Rdg + 5 LSD) @ 50 and 60 Hz |
DC Voltage | 600.0 V |
DC Voltage Basic Accuracy | +/-(0.5% Rdg + 5 LSD) |
AC Voltage | 600.0 V |
AC Voltage Basic Accuracy | +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz |
Resistance | 999.9 Ω |
Resistance Basic Accuracy | +/-(1.0% Rdg + 6 LSD) |
Frequency | 5.00 Hz to 500.0 Hz |
Frequency Basic Accuracy | +/-(0.5% Rdg +4 LSD) |
THD-F * | 0.0% to 99.9% |
THD-F * Basic Accuracy** | 1.5% of Reading + 6d @ Fund Frequency |
Active Power (W) | 0 to 600.0 kW |
Active Power (W) Basic Accuracy | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7 |
Reactive Power (VAR) | 0 to 600.0 kVAR |
Reactive Power (VAR) Basic Accuracy | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th PF > 0.7 |
Apparent Power (VA) | 0 to 600.0 kVA |
Apparent Power (VA) Basic Accuracy | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th |
Power Factor | 0.10 to 0.99 |
Power Factor Basic Accuracy | +/- 3 LSD @ Harmonics Fund to 21th |
Temperature | -58 °F to 572 ° F (-50 ° C to 300 ° C) |
Temperature Basic Accuracy | +/-(2.0% Rdg + 6 °F) +/-(2.0 % Rdg + 3 °C) |