Typical applications and use
- The broad working range and reliability has made 40AO-FV the preferred prepolarized microphone for coupler and ear simulator setups and is the natural supplement or replacement of existing solutions.
- It is used for production line testing in coupler setups for test of hearing aids, earphones, headphones, and headsets.
- The KEMAR Manikin can also be configured with 40AO-FV for wide-band binaural sound quality recordings.
- 40AO-FV can be used in
- GRAS IEC 60318-1 Ear Simulator RA0039
- GRAS IEC 60318-5 2cc Coupler RA0038 (incl. protection grid)
- GRAS KEMAR Manikin 45BA
- Other coupler systems can be configured with the 40AO-FV and a CCP preamplifier on request.
- The 40AO-FV is a very versatile microphone when connected to the RA0067 Transmitter Adapter for ½” Microphones. The 40AO becomes a high-impedance sound source when the RA0067 takes a calibration signal directly from the signal generator and makes the microphone behave like an electrostatic loudspeaker. In a coupler, this gives a frequency response that is as good as when the 40AO behaves like a microphone.
Compatibility
- The 40AO-FV requires a standardized ½” or ¼” CCP preamplifier and an input module that supports this technology with a BNC, SMB, or Microdot connector.
System verification
- For daily verification and check of your measurement setup, we recommend using a calibrator like GRAS Sound Level Calibrator 42AG.
- For proper sensitivity calibration, we recommend using a pistonphone like GRAS Intelligent Pistonphone 42AP.
Calibration
- When leaving the factory, all GRAS microphones have been calibrated in a controlled laboratory environment using traceable calibration equipment. Depending on the use, measurement environment and internal quality control programs we recommend that the microphone is recalibrated at least once a year.
- We offer two kinds of calibration as an optional after-sales service: GRAS Traceable Calibration and GRAS Accredited Calibration.
- GRAS Traceable Calibration is a traceable calibration performed by trained personnel under controlled conditions according to established procedures and standards. This is identical to the rigorous calibration that all GRAS microphones are subjected to as an integral part of our quality assurance.
- GRAS Accredited Calibration is performed by the GRAS Accredited Calibration Laboratory that has been accredited in accordance with ISO 17025 by DANAK, the Danish Accreditation Fund.
- If you want a new microphone set delivered with an accredited calibration in stead of the default factory calibration, specify this when ordering.
- Learn more at gras/calib.