- Hand-held portable, 153(L) x 93(W) x 30(H) mm
- 1G/250M Maximum sampling rate, 100Mbandwidth,2 channels.
- 8 Bit ~ 13 Bit vertical resolution.
- Open source hardware interface to support expansion modules.
- USB 2.0 interface, USB powered.Comes with PWM output.
- 72 hours long time data logger.
- Waveform recording and playback review.
- Support waveform image import as the comparison reference forreal-time waveform.
- Support Serial bus decoding (RS-232,RS-485/422, I²C, CAN,SPI,Lin).
- Supports a variety of current clamps and other physicalvolume custom probes.
- Support buffer waveform preview and mouse wheel operations.
- Historical change trend statistics and analysis functions.
- Pass / Fail detection.
- Support spectrum analysis and frequency response curvemapping.
- Support FIR Digital Filtering function.
- Support UI characteristic curve mapping.
SPECIFICATIONS:
l Connector type : | 2 channels with BNC sockets, 20 mm spacing. | ||
l Vertical resolution: | 8 Bit ~ 13 Bit . | ||
l Maximum sampling rate (S/s): | 250M (real time), 1G (equivalent) | ||
l Bandwidth ( −3 dB): | 100MHz | ||
l Input coupling: | AC/DC. | ||
l Input characteristics: | 1MΩ || 25pF. | ||
l PC OS requirements: | Windows XP, Win 7, Win 8.1, Win10 (32 bit and 64 bit). | ||
l Over-voltage protection: | ±60.0v (x1), ±600.0v (x10). (DC + AC peak) | ||
l Triggering type: | Rising/falling edge according to trigger level, Pulse width trigger. | ||
l Triggering mode: | None, auto, normal, single. | ||
l Pre-trigger capture: | 1%~99%of capture size. | ||
l Automatic measurements: | Maximum, minimum, average, RMS, frequency, period, positive pulse width, negative pulse width, duty cycle, rise time, peak-to-peak value. | ||
l Frequency response mapping | Scanning the frequency, record the process frequency and magnification data, and draw the frequency response curve. | ||
l Measurement statistical curve: | The historical trend of the automatically measured quantities can be plotted for statistics and analysis. | ||
l Pass / Fail detection: | You can set the upper and lower limits of the measurement quantity, and perform Pass / Fail detection and fault alarm function on the measured signal. | ||
l Deep measurement: | With this function, the waveform jump points are automatically numbered and marked, and the time difference between the two adjacent numbers is automatically displayed. | ||
l Samples Interpolation: | Linear or sin(x)/x. | ||
l FFT: | 1024 ~ 16K points. | ||
l FFT window function: | Rectangle, Hanning, Hamming, Blackman. | ||
l Math: | A+B, A-B, AxB, X-Y,Invert. | ||
l FIR Digital Filtering: | Low-pass,High-pass,Band pass,Band stop filter. | ||
l Acquisition Modes: | Normal mode / High Resolution mode / Peak detect mode. | ||
l Waveform recording | File format : | ||
and playback: | Record depth: | ||
File size: | |||
l Save as file: | txt, csv, excel, oscxxx, jpg. | ||
l Comparison reference | Support waveform image import and real-time waveform comparison reference. It can import waveform pictures, set gray level and transparency, move up and down, and zoom in and out horizontally and longitudinally. | ||
l Data logger Sampling Interval: | 1 second to 1 hour. | ||
l Data logger Record Duration: | 1 minute ~ 72 hours. | ||
l Temperature range: | Operating: 0 °C to 40 °C (20 °C to 30 °C for stated accuracy). Storage: −20 °C to +60 °C. | ||
l Reference Output: | 1K Hz, 1.5 V square wave output with 50% duty cycle. Software-configurable PWM output with adjustable frequency and duty cycle. | ||
l Size: | 153(L) x 93(W) x 23(H) mm. | ||
l Languages (full support): | English, Chinese (simplified). | ||
l Compliance: | CE, FCC. | ||
l Net weight: | 210 g. | ||
l Input sensitivity (10 vertical divisions): | 20 mV/div to 2 V/div. | ||
l Input ranges( probe x1): | ±100 mV to ±8 V full scale, in 7 ranges. | ||
l Input ranges( probe x10): | ±1V to ±80 V full scale, in 7 ranges. | ||
l Timebase selection (10 horizontal divisions): | 5 ns/div ~ 60 s/div, in 32 ranges. | ||
l Typical noise (peak to peak voltage): | 20 mV/div | 2 mV | |
50 mV/div | 5.8 mV | ||
100 mV/div | 8 mV | ||
200 mV/div | 22 mV | ||
500 mV/div | 38.8 mV | ||
1 V/div | 88.2 mV | ||
l Memory depth (byte /Ch): | 64K | ≤50 ms/div | |
258K | 200 ms/div | ||
645K | 500 ms/div | ||
2M | 1 s/div | ||
8M | 2 s/div | ||
10M | 10 s/div | ||
20M | 20 s/div | ||
30M | 30 s/div | ||
40M | 40 s/div | ||
50M | 50 s/div | ||
60M | 60 s/div | ||
l PC buffer: | Up to 500 frames of PC online data waveform buffer. | ||
l Trigger type: | Hardware | ||
l Trigger source: | Channel A | ||
l Power consumption: | 5 v || (248~279) mA | ||
l Protocols decoding: | UART/RS-232/485/422, I²C,CAN,SPI,lin | ||
l FIR Filtering: | Band-pass, Band-stop | ||
l Custom probes | Support two-point calibration of any current clamp on the market. |