Cable design
Construction | Material | Detail | Diameter |
---|---|---|---|
Center conductor | Copper, Tin plated | Strand-19, 0.19 mm | 0.9 mm |
Dielectric | PE (Polyethylene) | 2.95 mm | |
Outer conductor | Copper, Tin plated | Braid, 94% Coverage | 3.6 mm |
Outer conductor | Copper, Tin plated | Braid, 93% Coverage | 4.25 mm |
Jacket | LSFH (modified polyethylene) | RAL 9005 – bk | 5.4 mm ±0.1 |
Electrical data
Mechanical data
Environmental data
Nominal attenuation and power
Frequency (GHz) | Attenuation * (dB/m) | Attenuation * (dB/ft) | CW Power ** (W) |
---|---|---|---|
0.01 | 0.045 | 0.014 | 1000 |
0.05 | 0.103 | 0.031 | 447 |
0.10 | 0.148 | 0.045 | 316 |
0.15 | 0.184 | 0.056 | 258 |
0.20 | 0.215 | 0.065 | 224 |
0.25 | 0.242 | 0.074 | 200 |
0.30 | 0.267 | 0.081 | 183 |
0.45 | 0.334 | 0.102 | 149 |
0.50 | 0.354 | 0.108 | 141 |
0.55 | 0.373 | 0.114 | 135 |
0.60 | 0.392 | 0.120 | 129 |
0.65 | 0.410 | 0.125 | 124 |
0.70 | 0.428 | 0.130 | 120 |
0.75 | 0.445 | 0.136 | 115 |
0.80 | 0.462 | 0.141 | 112 |
0.85 | 0.478 | 0.146 | 108 |
0.90 | 0.494 | 0.151 | 105 |
0.95 | 0.509 | 0.155 | 103 |
1.00 | 0.525 | 0.160 | 100 |
1.50 | 0.665 | 0.203 | 82 |
2.00 | 0.790 | 0.241 | 71 |
2.50 | 0.904 | 0.276 | 63 |
3.00 | 1.012 | 0.308 | 58 |
3.50 | 1.114 | 0.340 | 53 |
4.00 | 1.212 | 0.370 | 50 |
4.50 | 1.307 | 0.398 | 47 |
5.00 | 1.398 | 0.426 | 45 |
6.00 | 1.574 | 0.480 | 41 |