Cable design
Construction | Material | Detail | Diameter |
---|---|---|---|
Center conductor | Copper | Strand-07, 0.16 mm | 0.49 mm |
Dielectric | PE (Polyethylene) | 1.5 mm | |
Outer conductor | Copper | Braid, 96% Coverage | 2.0 mm |
Outer conductor | Copper | Braid, 93% Coverage | 2.5 mm |
Jacket | PVC II (low migration) | RAL 9005 – bk | 3.1 mm ±0.1 |
Electrical data
Operating frequency: | ≤ 6 GHz |
Impedance: | 50 ± 2 Ω |
Capacitance (pF/m): | 101 |
Propagation velocity (% of c): | 66 |
Signal delay (ns/m): | 5,03 |
Insulation resistance dielectric: | ≥ 100000000 MΩm |
Operating Voltage (at sea level): | ≤ 1.5 kVrms |
Test voltage: | ≤ 3 kVrms |
Screening effectiveness: | ≤ 78 dB (from 0.001 GHz up to 1 GHz) |
Mechanical data
Weight (kg/100 m): | 2,1 |
Static bending radius: | ≥ 15 mm |
Repeated bending radius: | 30 mm |
Environmental data
Operation temperature: | -25 °C to +85 °C |
Installation temperature: | -20 °C to +60 °C |
2011/65/EC (RoHS): | |
2006/1907/EC (REACH): |
Nominal attenuation and power
Frequency (GHz) | Attenuation * (dB/m) | Attenuation * (dB/ft) | CW Power ** (W) |
---|---|---|---|
0.01 | 0.078 | 0.024 | 380 |
0.05 | 0.177 | 0.054 | 170 |
0.10 | 0.254 | 0.077 | 120 |
0.15 | 0.315 | 0.096 | 98 |
0.20 | 0.367 | 0.112 | 85 |
0.25 | 0.414 | 0.126 | 76 |
0.30 | 0.457 | 0.139 | 69 |
0.45 | 0.571 | 0.174 | 57 |
0.50 | 0.605 | 0.184 | 54 |
0.55 | 0.638 | 0.194 | 51 |
0.60 | 0.669 | 0.204 | 49 |
0.65 | 0.700 | 0.213 | 47 |
0.70 | 0.730 | 0.223 | 45 |
0.75 | 0.759 | 0.231 | 44 |
0.80 | 0.787 | 0.240 | 42 |
0.85 | 0.815 | 0.248 | 41 |
0.90 | 0.842 | 0.257 | 40 |
0.95 | 0.868 | 0.265 | 39 |
1.00 | 0.894 | 0.273 | 38 |
1.50 | 1.132 | 0.345 | 31 |
2.00 | 1.342 | 0.409 | 27 |
2.50 | 1.535 | 0.468 | 24 |
3.00 | 1.717 | 0.523 | 22 |
3.50 | 1.889 | 0.576 | 20 |
4.00 | 2.053 | 0.626 | 19 |
4.50 | 2.212 | 0.674 | 18 |
5.00 | 2.366 | 0.721 | 17 |
6.00 | 2.661 | 0.811 | 16 |