Features
.Support logic analyzer and multimeter
.2GSa/s sampling rate and 50GSa/s equivalent sampling rate
.1024k channel memory depth
.5.7-inch color LCD display
.USB-host/device and option LAN, GPIB interface
Technical Data | DQ1042C | DQ1062C | DQ1102C | DQ1152C | DQ1202C |
Channels | 2 external + logical analyzer + multimeter | ||||
Sampling rate | 2GSa/s | ||||
Equivalent sampling rate | 50GSa/s | ||||
Display | |||||
Type | 5.7″ rectangle color LCD | ||||
Backlight intensity | 300 ni | ||||
Display resolution | 320 horizontal x 240 vertical pixels | ||||
Vertical system | |||||
Sensitivity and accuracy | 1mV/div~10V/div | ||||
Vertical resolution | 8 bit | ||||
Width of band (-3dB) | DC (AC 5Hz) ~ 40MHz | DC (AC 5Hz) ~ 60MHz | DC (AC 5Hz) ~ 100MHz | DC (AC 5Hz) ~ 150MHz | DC (AC 5Hz) ~ 200MHz |
Selectable analog bandwidth limit | 20MHz | ||||
Rise time | ≤8.7ns | ≤5.8ns | ≤3.5ns | ≤2.3ns | ≤1.8ns |
DC gain Accuracy | ±5%(1mV/div) | ±4%(2mV/div) | ±3%(5mV/div~10V/div) | ||
DC measurement accuracy | ±(5%+0.1div)(1mV/div) | ±(5%+0.1div)(1mV/div) | ±(5%+0.1div)(1mV/div) | ||
Horizontal system | |||||
SEC/DIV range | 2ns~50s/div(200MHz, 150MHz) | ||||
5ns~50ns/div(100MHz~40MHz), at 1-2-5 increment | |||||
Waveform interpolation | Sin(x)/x | ||||
Recording length | 1024k | ||||
Sampling rate and delay time accuracy | ±50ppm (any time interval 1ms) | ||||
Delta time measurement accuracy | Single: ±(1 sampling time interval + 50ppm rdg. + 0.6ns) | ||||
Average values: ±(1 sampling time interval + 50ppm rdg. + 0.4ns) | |||||
Trigger system | |||||
Mode | Auto, normal, single | ||||
Type | Edge, pulse, video, alternate | ||||
Hold off range | 100ns~1.5s | ||||
Math | +, -, x, ÷ | ||||
FFT | |||||
Acquire input | |||||
Input coupling | DC, GND, AC | ||||
Input impedance | 1MΩ±1.5% 24pF±3pF | ||||
Probe attenuation | 1x, 10x, 100x, 1000x | ||||
Max. input voltage | 400V (DC+AC peak) | ||||
Measurement | |||||
Cursor | Voltage difference ( V) between cursors Time difference ( T) between cursors Reciprocal of T in Hz (1/ T) | ||||
Auto-measure | Vrms, Vavg, Vp-p, Vmax, Vmin, Vtop, Vhigh, Vlow, Vmid, Vamp; Period, Freq, Rise, Fall, +Width, -Width, +Duty, -Duty, Delay | ||||
I/O | |||||
Standard | USB(D), USB(H) | ||||
Options | GPIB, LAN | ||||
Calibrator | |||||
Output voltage | 3V≥( 1MΩ load) | ||||
Output frequency | 1kHz | ||||
Logical analyzer | |||||
Input channel | 200MSa/s | ||||
Max. sampling rate | D0~D15 | ||||
Recording length | 512k | ||||
Max. input voltage | ±40Vpeak | ||||
Minimum voltage slew | 1.2Vpp | ||||
Trigger mode | Code | D0~D15 Trigger code: H, L, X Clock edge: Rise, Fall | |||
Persist | D0~D15 Trigger code: H, L, X Condition: >, <, = Persist setup: 20ns~10s | ||||
Digital multimeter characterizes | |||||
DC voltage | Range | 400.0mV/4.000V/40.00V/400.0V | |||
Accuracy | ±(1%+5digits) | ||||
AC voltage (40Hz~400Hz) | Range | 400.0mV/4.000V/40.00V/400.0V | |||
Accuracy | ±(1.2%+5digits) | ||||
Resistance | Range | 400Ω/4kΩ/40kΩ/400kΩ/4MΩ/40MΩ | |||
Accuracy | ±(1.5%+5digits) | ||||
On/off | <70.0Ω | ||||
Diode | Forward voltage drop 0.5~0.8V | ||||
DC current | Range | 4mA/40mA/400mA | |||
Accuracy | ±(1%+5digits) | ||||
Range | 4A | ||||
Accuracy | ±(1.5%+5digits) | ||||
Power source | 100~240VACrms, 45~440Hz; 50VA Max; CAT II | ||||
Dimensions (Wx Hx D) | 320mm x 150mm x 130mm | ||||
Weight | 2.5kg | ||||
Accessories | Operation manual, adapter, probex 2, multimeter penx2, current-voltage convertor modulex 2 |