Description
The FTH series is a high-power DC switching power supply with the advantages of high power, high current, low ripple noise, fast transient response, high resolution, and high precision. It can be applied to laboratory test, vehicle equipment test, solar inverter test, DC/DC converter and inverter test, engine start test, automatic battery charging, electronic product life cycle test, etc.
The FTH Series offer many unique advantages for telecom, automated test system & integration, industrial, battery charge & simulation, electric cars and motors. These advantages include a high power density of 15KW in 3U, precision readback of output current and voltage, output trigger signals, as well as the ability to create complex DC transient waveforms to test device behavior to spikes, drops, and other voltage deviations.
The FTH series programmable DC power supply includes more than 100 different models, ranging from 5kW to 15kW, up to 1500V and up to 1200A. For high-power applications, parallel up to 5 units for up to 75kW through master-slave mode.
Feature
❏ CV, CC, CP modes;
❏ Easy Master / Slave parallel & series operation up to 75KW;
❏ 16-bit readback capability for precision V & I measurement;
❏ Programmable sequence waveforms;
❏ Voltage & current slew rate control;
❏ 1ms typical transient response;
❏ High slew rate models are available;
❏ 0.01% source effect, 0.02% load effect, 0.02% ripple;
❏ Remote sense voltage compensation;
❏ Digital/analog composite signal monitor & control port;
❏ OVP, OCP, OPP, OTP, LVP, etc. protections;
❏ Standard RS232, LAN, optional GPIB ports;
❏ Support SCPI protocol;
FTH has high slew rate models up to 40V/ms and 150A/ms
Specification
General specification | |
Item | Specification |
AC Input | 3 Phase input, 340VAC ~ 420VAC, 47Hz ~ 63Hz |
Output Voltage | 0 ~ rated voltage(Max 1500V) |
Output Current | 0 ~ rated current(Max 1200A) |
Output Power | 0 ~ rated power |
Efficiency | 0.87(Typical) |
Line Regulation | Voltage: 0.01%F.S.; Current: 0.05%F.S. |
Load Regulation | Voltage: 0.02%F.S.; Current: 0.1%F.S. |
Analog Programming | V/I control; Support programming voltage: DC 0 ~ 5V/DC 0 ~ 10V input |
Voltage Measurement Accuracy | 0.1%+0.1%F.S. |
Current Measurement Accuracy | 0.1%+0.2%F.S. |
Voltage & Current Monitoring | Voltage/Current monitoring output voltage: DC 0 ~ 10V |
Protection | OVP/OCP/OPP/RVP/LVP/OTP |
Transient Response | Typical 1ms |
Voltage Temperature Coefficient | 20ppm/℃ |
Current Temperature Coefficient | 40ppm/℃ |
Display | 4.3’’ TFT color LCD |
Operation | Function key, number key, and knobs |
Communication Ports | Standard RS232, LAN |
Storage | 20 groups of fast recall parameters +8 sequence files |
Cooling | Air cooling |
Working Temperature | 0℃ ~ 40℃ |
Storage Temperature | -20℃ ~ 70℃ |
Altitude | <2000m |
Specification – 1 | ||||||||
Model | FTH040-010 | FTH045-015 | FTH050-020 | FTH050-030 | FTH050-040 | FTH050-050 | FTH050-060 | FTH050-100 |
Output Voltage | 0~10V | 0~15V | 0~20V | 0~30V | 0~40V | 0~50V | 0~60V | 0~100V |
Current | 0~400A | 0~300A | 0~250A | 0~167A | 0~125A | 0~100A | 0~83.5A | 0~50A |
Power | 4kW | 4.5kW | 5kW | |||||
Model | FTH080-010 | FTH090-015 | FTH100-020 | FTH100-030 | FTH100-040 | FTH100-050 | FTH100-060 | FTH100-100 |
Output Voltage | 0~10V | 0~15V | 0~20V | 0~30V | 0~40V | 0~50V | 0~60V | 0~100V |
Current | 0~800A | 0~600A | 0~500A | 0~334A | 0~250A | 0~200A | 0~167A | 0~100A |
Power | 8kW | 9kW | 10kW | |||||
Model | FTH120-010 | FTH135-015 | FTH150-020 | FTH150-030 | FTH150-040 | FTH150-050 | FTH150-060 | FTH150-100 |
Output Voltage | 0~10V | 0~15V | 0~20V | 0~30V | 0~40V | 0~50V | 0~60V | 0~100V |
Current | 0~1200A | 0~900A | 0~750A | 0~500A | 0~375A | 0~300A | 0~250A | 0~150A |
Power | 12kW | 13.5kW | 15kW | |||||
Voltage Ripple | ||||||||
V(p-p) | 55mV | 60mV | 60mV | 65mV | 75mV | 75mV | 115mV | 135mV |
V(rms) | 20mV | 20mV | 20mV | 20mV | 20mV | 20mV | 25mV | 25mV |
Voltage Programming | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.1%F.S. | |||||||
Current Programming | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.2%F.S. | |||||||
External Analog Programming | ||||||||
Control Voltage | 0~5V or 0~10V corresponds to 0~100%F.S. | |||||||
Voltage Accuracy | 0.2%F.S. | |||||||
Current Accuracy | 0.5%F.S. | |||||||
Output Accuracy | 0.5%F.S. | |||||||
Line Regulation | ||||||||
Voltage | 0.05%F.S. | 0.01%F.S. | ||||||
Current | 0.05%F.S. | |||||||
Load Regulation | ||||||||
Voltage | 0.05%F.S. | 0.02%F.S. | ||||||
Current | 0.1%F.S. | |||||||
Voltage Measurement | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.1%F.S. | |||||||
Current Measurement | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.2%F.S. | |||||||
Others | ||||||||
Dimension(mm) | 482.6(W)*132.5(H)*600(L) | |||||||
Weight | 18.5kg/5kW; 25kg/10kW; 31.5kg/15kW |
Specification – 2 | ||||||||
Model | FTH050-160 | FTH050-300 | FTH050-500 | FTH050-600 | FTH050-800 | FTH050-1000 | FTH050-1200 | FTH050-1500 |
Output Voltage | 0~160V | 0~300V | 0~500V | 0~600V | 0~800V | 0~1000V | 0~1200V | 0~1500V |
Current | 0~31.5A | 0~17A | 0~10A | 0~8.5A | 0~6.5A | 0~5A | 0~4A | 0~3.5A |
Power | 5kW | |||||||
Model | FTH100-160 | FTH100-300 | FTH100-500 | FTH100-600 | FTH100-800 | FTH100-1000 | FTH100-1200 | FTH100-1500 |
Output Voltage | 0~160V | 0~300V | 0~500V | 0~600V | 0~800V | 0~1000V | 0~1200V | 0~1500V |
Current | 0~62.5A | 0~33.5A | 0~20A | 0~17A | 0~12.5A | 0~10A | 0~8.5A | 0~7A |
Power | 10kW | |||||||
Model | FTH150-160 | FTH150-300 | FTH150-500 | FTH150-600 | FTH150-800 | FTH150-1000 | FTH150-1000 | FTH150-1500 |
Output Voltage | 0~160V | 0~300V | 0~500V | 0~600V | 0~800V | 0~1000V | 0~1200V | 0~1500V |
Current | 0~94A | 0~50A | 0~30A | 0~25A | 0~19A | 0~15A | 0~12.5A | 0~10A |
Power | 15kW | |||||||
Voltage Ripple | ||||||||
V(p-p) | 175mV | 200mV | 350mV | 350mV | 500mV | 650mV | 750mV | 850mV |
V(rms) | 25mV | 40mV | 50mV | 60mV | 80mV | 100mV | 120mV | 140mV |
Voltage Programming | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.1%F.S. | |||||||
Current Programming | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.2%F.S. | |||||||
External Analog Programming | ||||||||
Control Voltage | 0~5V or 0~10V corresponds to 0~100%F.S. | |||||||
Voltage Accuracy | 0.2%F.S. | |||||||
Current Accuracy | 0.5%F.S. | |||||||
Output Accuracy | 0.5%F.S. | |||||||
Line Regulation | ||||||||
Voltage | 0.01%F.S. | |||||||
Current | 0.05%F.S. | |||||||
Load Regulation | ||||||||
Voltage | 0.02%F.S. | |||||||
Current | 0.1%F.S. | |||||||
Voltage Measurement | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.1%F.S. | |||||||
Current Measurement | ||||||||
Resolution | 16Bits | |||||||
Accuracy | 0.1%+0.2%F.S. | |||||||
Others | ||||||||
Dimension(mm) | 482.6(W)*132.5(H)*600(L) | |||||||
Weight | 18.5kg/5kW;25kg/10kW;31.5kg/15kW |
Specification – 3 | ||||
Model | FTH040-010H | FTH045-015H | FTH050-020H | FTH050-030H |
Output Voltage | 0~10V | 0~15V | 0~20V | 0~30V |
Current/Power | 0~400A/4kW | 0~300A/4.5kW | 0~250A/5kW | 0~167A/5kW |
Model | FTH080-010H | FTH090-015H | FTH100-020H | FTH100-030H |
Output Voltage | 0~10V | 0~15V | 0~20V | 0~30V |
Current/Power | 0~800A/8kW | 0~600A/9kW | 0~500A/10kW | 0~334A/10kW |
Model | FTH120-010H | FTH135-015H | FTH150-020H | FTH150-030H |
Output Voltage | 0~10V | 0~15V | 0~20V | 0~30V |
Current/Power | 0~1200A/12kW | 0~900A/13.5kW | 0~750A/15kW | 0~500A/15kW |
Voltage Slew Rate | 0.001V/ms~5V/ms | |||
Current Slew Rate | 0.001A/ms~150A/ms | |||
Voltage Ripple | ||||
V(p-p) | 55mV | 60mV | 60mV | 65mV |
V(rms) | 20mV | 20mV | 20mV | 20mV |
Voltage Programming | ||||
Resolution | 16Bits | |||
Accuracy | 0.1%+0.1%F.S. | |||
Current Programming | ||||
Resolution | 16Bits | |||
Accuracy | 0.1%+0.2%F.S. | |||
External Analog Programming | ||||
Control Voltage | 0~5V or 0~10V corresponds to 0~100%F.S. | |||
Voltage Accuracy | 0.2%F.S. | |||
Current Accuracy | 0.5%F.S. | |||
Output Accuracy | 0.5%F.S. | |||
Line Regulation | ||||
Voltage | 0.05%F.S. | |||
Current | 0.05%F.S. | |||
Load Regulation | ||||
Voltage | 0.05%F.S. | |||
Current | 0.1%F.S. | |||
Voltage Measurement | ||||
Resolution | 16Bits | |||
Accuracy | 0.1%+0.1%F.S. | |||
Current Measurement | ||||
Resolution | 16Bits | |||
Accuracy | 0.1%+0.2%F.S. | |||
Others | ||||
Dimension(mm) | 482.6(W)*132.5(H)*694.5(L) | |||
Weight | 23kg/5kW;30kg/10kW;38kg/15kW |
Specification – 4 | |||
Model | FTH050-600H | FTH050-1000H | |
Output Voltage | 0~600V | 0~1000V | |
Current/Power | 0~8.5A/5kW | 0~5A/5kW | |
Model | FTH100-600H | FTH100-1000H | |
Output Voltage | 0~600V | 0~1000V | |
Current/Power | 0~17A/10kW | 0~10A/10kW | |
Model | FTH150-600H | FTH150-1000H | |
Output Voltage | 0~600V | 0~1000V | |
Current/Power | 0~25A/15kW | 0~15A/15kW | |
Rise Time | 50%F.S. CC Load | 30ms | 25ms |
No Load | 30ms | 25ms | |
Fall Time | 50%F.S. CC Load | 30ms | 25ms |
10%F.S. CC Load | 100ms | 80ms | |
No Load | 1.2s | 3s | |
Voltage Slew Rate | 0.001V/ms – 20V/ms | 0.001V/ms – 40V/ms | |
Current Slew Rate | 0.001A/ms – 2A/ms | ||
Voltage Ripple | |||
V(p-p) | 1500mV | 2550mV | |
V(rms) | 650mV | 1950mV | |
Voltage Programming | |||
Resolution | 16Bits | ||
Accuracy | 0.1%+0.1%F.S. | ||
Current Programming | |||
Resolution | 16Bits | ||
Accuracy | 0.1%+0.2%F.S. | ||
External Analog Programming | |||
Control Voltage | 0~5V or 0~10V corresponds to 0~100%F.S. | ||
Voltage Accuracy | 0.2%F.S. | ||
Current Accuracy | 0.5%F.S. | ||
Output Accuracy | 0.5%F.S. | ||
Line Regulation | |||
Voltage | 0.01%F.S. | ||
Current | 0.05%F.S. | ||
Load Regulation | |||
Voltage | 0.02%F.S. | ||
Current | 0.1%F.S. | ||
Voltage Measurement | |||
Resolution | 16Bits | ||
Accuracy | 0.1%+0.1%F.S. | ||
Current Measurement | |||
Resolution | 16Bits | ||
Accuracy | 0.1%+0.2%F.S. |