Typical Application
- Insulation test for general purpose electric instruments, transformers, batteries, etc.
Model Designation
Code | Description |
---|---|
X | RS-232C |
04 | RS-232C + BCD (open collector) |
Measuring Range
Test voltage | Resistance range | Accuracy | ||
---|---|---|---|---|
± (2% of rdg.+3 digit) | ± 5% of rdg. | ± 30% of rdg. | ||
DC 25 V ~ DC 99 V | 2.000 MΩ | 0.000~2.000 MΩ | – | 2.010~4.990 MΩ |
20.00 MΩ | 1.80~20.00 MΩ | – | 20.10~49.90 MΩ | |
200.0 MΩ | 18.0~100.0 MΩ | 100.1~200.0 MΩ | 201.0~999.0 MΩ | |
DC 100 V ~ DC 499 V | 2.000 MΩ | 0.000~2.000 MΩ | – | 2.010~4.990 MΩ |
20.00 MΩ | 1.80~20.00 MΩ | – | 20.10~49.90 MΩ | |
200.0 MΩ | 18.0~100.0 MΩ | 100.1~200.0 MΩ | 201.0~499.0 MΩ | |
2000 MΩ | – | 180 ~2000 MΩ | 2010 ~5000 MΩ | |
DC 500 V ~ DC 1000 V | 20.00 MΩ | 0.00~20.00 MΩ | – | 20.10~49.90 MΩ |
200.0 MΩ | 18.0~200.0 MΩ | – | 201.0~499.0 MΩ | |
2000 MΩ | 180 ~1000 MΩ | 1001 ~2000 MΩ | 2010 ~9990 MΩ |
Basic Specifications
Output voltage | DC 25~1050 V (Resolution: 1 V), Open voltage: ±(1% + 5 V) of output voltage |
---|---|
Open circuit voltage | Less than 130 % of rated voltage |
Rated current | Less than 1 mA |
Display | Measured value: 0~9990 2.7 inch organic EL display (OLED), color: green |
Sampling cycle |
|
Response speed (During NG judgement) |
|
Parameter hold | Memorize and hold the parameter with EEPROM for 10 years. |
Insulation resistance | All terminals – External case: DC500V More than 100 MΩ |
Withstand voltage | All terminals – External Case: DC 2000 V 1min. All terminals – External Case: DC 500V more than 100 MΩ
Measurement terminals – control input/output terminals and data input/output terminals: AC 1500 V 1min. |
Power supply | AC 100~240 V(50/60 Hz) |
Power consumption | 28 VA MAX. |
Operating environment | 0~50°C, less than 90% RH(no condensation) |
Storage environment | -20~70°C, less than 70% RH (no condensation) |
Size | 205(W)×64(H)×169(D)mm(not included protuberance) |
Weight | |
Accessories | Power cord (1), Fuse (1), Operating manual (1) |