Performance Characteristics
- ■ Waveform sampling rate is 100Msps/200Msps, storage depth is 6.5kBytes
■ 7 inch 65k color 16: 9 TFT display, resolution is 800×480
■ Comparison of four waveforms: area, area difference, corona and phase difference.
■ Excellent test repeatability can ensure stable and consistent test results
■ The horizontal stretching & movement of the waveform and amplitude of the zoom can meet your all-round vision.
■Powerful corona extraction function can detect the insulation problems of the potential product early.
■ It has the automatic storage function after Instrument parameters being modified, boot files can be automatically loaded.
■ Standard automatic acquisition function help you automatically select the appropriate sampling rate,
■ Destructive tests make you choose the right test voltage.
■ The application of the demagnetizing pulse ensures that the test waveform is consistent.
■ Standard sample averaging function can process the standard waveform averaging up to 32 times.
■ The firmware version can be upgraded and updated by
USB HOST.
■ U disk can support file systems with format FAT16, FAT32,the current screen image or waveform data can be quickly saved through the instrument panel shortcut keys.
■ Standard RS232C、HANDLER、USB HOST,USB device optional GPIB、LAN interface.
Brief Introduction
- UC5800 series Impulse winding tester adopts the most popular 7-inch 800×480 color TFT LCD display, a mainstream high-performance 32-bit processor and high-speed FPGA is also used. UC5800 series providing a sampling rate 100 Msps/200Msps and a sampling storage depth of 6.5k bytes,which make the test more accurate. At the same time the instruments series also use a high-voltage power supply with high stability and the high-voltage switching devices controlled by thyristor module,so the accuracy, stability and reliability of the product’s test can be improved greatly. All the present popular interface functions are provided by this series of instruments, data communication with PC, remote control and graphics storage in real time can be easily realized.
Ordering Information
- UC5800 series Impulse winding tester
Instrument Accessories
- UC26035 high voltage test cables
UC6801-01 Pedal start switch
power cable
Test Interface
- Sampling rate is up to 100Msps/200Msps, which can actually reflect the size of the corona mass produced by the coil test.
Instrument type | UC5813 | UC5813A | UC5815 | UC5815A | ||
Pulse voltage | 100V~3000 V, 10V for the step, Voltage accuracy is ±5%+15V |
100V~5000 V, 10V for the step, Voltage accuracy is ±5%+15V |
||||
Channel numbers | 1 channel | |||||
Sampling rate | 100Msps | 200Msps | 100Msps | 200Msps | ||
Measurement speed | 12 times/sec | |||||
Pulse energy | Maximum is 0.09 J | Maximum is 0.25 J | ||||
Inductance test range | ≥10μH | |||||
The number of applied pulses | Test pulse is up to 32 times at most, degaussing pulse is up to 16 times at most | |||||
Input impedance | 10MΩ | |||||
Waveform acquisition | Sampling rate of 100Msps can be 10 grade adjustable Sampling rate of 200Msps can be 11 grade adjustable Sampling resolution: 8 Bits Waveform storage depth : 6500 Bytes Sample average :1-32 |
|||||
Display screen | 7 inch 65k color 800 * 480 dot TFT display waveform display range 650×256,support x2,x3times enlarge |
|||||
Judgment method | Area, area difference, corona, phase difference | |||||
Waveform parameter measurement | Voltage, frequency, time | |||||
Test accuracy of repeatability | ±1% | |||||
Trigger mode | Manual trigger, external trigger, bus trigger, internal trigger | |||||
Output distinguish | OK/NG screen display, LED lights instructions, buzzer alarm | |||||
Measurement statistics | With statistical function of measurement results | |||||
Memory | internal | Store 300 groups of waveform data and instrument parameters’ setting | ||||
external | Store 600 groups of waveform data and instrument parameters’ setting | |||||
Interface | Standard RS232C、HANDLER、USB HOST,USB Device,optional GPIB、LAN interface |