Descriptions
The model 8528 is withstand voltage tester having output voltage 5kV, output capacity 500VA. Withstand voltage test of electrical equipment and parts can be done based on various safety standards. Interlock function, key lock function and test condition memory function are standard features and it seeks safety and easy operation. In addition, the external control is easy, the standard features have remote control, interface test conditions and status output to output the judgment result and can take advantage of system architecture of automatic test.
Basic Specifications
Measurement voltage | AC 0 to 2.5 kV, 0 to 5.0 kV, 2 ranges |
---|---|
voltage output system | Zero-cross throw switch |
Setting of voltage | Manual setting by volt slider |
Accuracy of Voltage | ± 1.5% of F.S. |
Measurement current | From 0.01 mA to 110.0 mA |
Accuracy of current | ± ( 5% + 20 μA ) for high setting value |
Setting time | 0.5 to 999 s (with timer OFF function) |
judgement of test result | High & low limit |
Power supply | 90 to 110 V AC, 50/60 HZ (Available 115/200/220/240 V) |
Weight | Approx. 15 kg (20.5kg for optional power supply) |
Dimensions | 320 (W) x 150 (H) x 330 (D) mm |
Accessories | 2 m High-voltage cable, 3 m Earth wire, 2.5 m Power cord, Remote I/O plug, Fuse |