Descriptions
MICROTEST 6365A/6367A LCR Meter provides a frequency range of 0.1Hz to 200k/1MHz and is suitable for applications such as electrochemical impedance or battery material testing. With an extremely low starting frequency of 0.1Hz, it can accurately measure parameters such as |Z| (impedance), |Y| (admittance), θ (phase angle), X (reactance), R (series/parallel resistance), G (conductance), B (susceptance), L (inductance), D (dissipation factor), Q (quality factor), DCR (DC resistance), and C (capacitance). It supports communication interfaces such as RS-232, Handler, LAN, USB Host, GPIB, and allows storage of test screens and data via USB. With the optional PC connection software, it also enables sweep analysis capabilities.
Features
- Ultra Low Frequency 0.1Hz-200k/1MHz
- Output Impedance 100Ω
- Open Circuit/Short Circuit
- Meter Mode
- List Mode
- 7.0″ TFT, 800×480 color screen
- Four Parameters Displayed Simultaneously
- Comparator/BIN
- Basic Accuracy ±0.05%
- Using Graphical Analysis by PC Link
- RS-232、Handler、LAN、USB Host 、Handler、GPIB
Model | 6365A / 6367A | |||||
Frequency | 0.1Hz-200kHz (6365A) 0.1Hz-1MHz (6367A) |
SPEC
Frequency Setting | Continuity | |
Frequency Output Accuracy | ±0.01% | |
Frequency Resolution | 5 Digits | |
Basic Accuracy | ±0.05% | |
AC Drive Level | Test Signal Voltage Level | 10mV – 2Vrms |
Voltage Minimum Resolution | 1mV | |
DC Drive Level | Test Signal Voltage Level | 10mV – 2V |
Voltage Minimum Resolution | 1mV | |
Output Impedance | 100Ω | |
Measurement Mode | Meter mode, list mode | |
Measurement Parameters | |Z|、|Y|、θ、X、R、G、B、L、D、Q、DCR、C | |
Test Time | AC / DC test speed Max. 8mS |
Measurement Parameters
Parameters | Range |
|Z| | 0.001mΩ – 99.999MΩ |
R, X | 0.001mΩ – 99.999MΩ |
|Y| | 0.1nS – 99.999S |
G, B | 0.1nS – 99.999S |
θ | ±0.001 ~ ±180.000deg |
Cs, Cp | 0.01pF – 9.9999F |
Ls, Lp | 0.1nH – 99.999KH |
D | 0.00001 – 9.9999 |
Q | 0.1 – 9999.9 |
Δ | -9999% – 9999% |
Rdc | 0.001mΩ – 99.999MΩ |
SYSTEM
Measurement Circuit | Series/Parallel |
Correction | Open Circuit/Short Circuit |
Indicator | PASS/FAIL |
Test Range | Automatic/Lock |
BIN | ● |
List Mode | 8 sets |
Bulit-in Storge | 128 sets |
USB Host Storge | LCR setting documents, list mode setting document |
Trigger Test | Auto, manual, RS-232, GPIB, Handler |
Power Supply | Voltage:98-132Vac or 195-264Vac (Switchable) |
Frequency:47-63Hz | |
Power consumption | 30VA |
Environment | Temperature:10℃-40℃ |
Humidity:20-90%RH | |
Dimension | 358x148x343 mm (W*H*D) |
Weight | 3 Kg |
Interface | RS-232、Handler、LAN、USB Host |
Display | Color Screen, 7″ TFT (800*480) |