- ■ Switching transformer scanning test, comprehensive characteristics analysis.
- ■ Network transformer scanning test, comprehensive characteristics analysis
- ■ Discrete passive components (L, R, C) multi-channel scanning test
- ■ Relay drive line package, contact resistance multi-channel scanning test
- ■ Multi-channel DC resistance DCR scanning test
- ■ Comprehensive test analysis of multiple passive components in impedance network
Technical Parameter
Model TH2832XA TH2832XB TH2832XC Number of Test Pin 24 24 12 Test Signal Frequency 20Hz-200kHz, 15025 points in total. Display 4.3 inch TFT LCD 272*480 Transformer Test Parameter Turn ratio, turs, phase, L, C, Lk, Q, ACR, DCR, Balance, Pin short. LCR Test Parameter |Z|,Y|, C, L, X, B, R, G, D, Q, θ, DCR, Turn-ratio, Phase, Lk. No LCR function Basic Accuracy LCRZ 0.1% —— DCR, Turn ratio 0.5% Signal Source Output Impedance 30Ω, 100Ω selectable. Test Speed (≥10 kHz) Fast: 40ms, Med: 125ms, Slow: 370ms. AC Signal Level 10mV – 2Vrms, 100μA – 20mArms. DC Bias Voltage Source 0V – ± 5V, 0mA –±50mA. Comparator Function 10-bin sorting, PASS/FAIL indicator, count function Memory 100 groups of LCRZ setting file,100 groups of transformer scan set file, 10 groups of gif file.
Easy to buy